Article Contents
Industry Insight: Lighting On Outside Of House

Introduction: Industrial-Grade Exterior Lighting Is No Longer Optional
The line between “residential” and “commercial” outdoor lighting has disappeared.
Municipalities, mixed-use developers, and large-scale EPCs now specify the same photometric files, surge immunity, and IP ratings for a driveway column as they do for a freeway interchange.
For distributors and project managers this convergence means one thing: every luminaire crossing your warehouse must already carry ETL or TUV CE documentation, or you risk container-load rejections, on-site re-inspections, and schedule penalties.
Why Certification Becomes the Deciding Factor
| Risk Vector | Non-Certified Generic | ETL / TUV CE Certified |
|---|---|---|
| Port-of-Entry Hold | 8–18 days average | <24 h release (CB Scheme) |
| Insurance Underwriting | +15 % premium | Standard rate |
| Warranty Claim Rate | 5–7 % | <0.3 % (Beauty STC 2023 data) |
| Re-lamping Cycles | 2–3 years | L90 >54 000 h @ 50 °C Ta |
ETL and TUV CE are not stickers—they are factory-audit protocols that verify driver isolation, 4 kV surge, and –40 °C cold-start.
When your customer’s PE stamps the electrical drawings, those numbers become his liability.
Beauty STC Lighting – 1998 to Present
Founded in Jiangmen’s High-tech Industrial Zone the same year LED efficacy crossed 25 lm/W, Beauty (STC) Manufacturing Co., Ltd has shipped 280 million metres of flexible strip and 3.2 million flood- and area-luminaires to 52 countries.
Our in-house CNAS-accredited lab pre-certifies every outdoor SKU to both ETL (UL 1598/8750) and TUV CE (EN 60598-2-5, EN 62368), slashing third-party lead-times by 18 days and eliminating the “sample swap” risk that plagues low-margin suppliers.
OEM/ODM Capability at Factory-Direct Scale
| Service Module | Specification |
|---|---|
| Tooling | 600 t Die-cast, 1 500 t Cold-chamber, in-house powder-coat line |
| Optics | IES Type II, III, IV distributions, 2-step MacAdam ellipse |
| Drivers | 1–10 V, DALI-2, Zhaga Book 18 dimming, 6 kV/10 kA surge options |
| Ingress | IP66 & IP67 standard; IP69K for coastal ammonia environments |
| Surface Finish | AkzoNobel Interpon 610 (1 000 h salt spray) or marine-grade 316L |
Whether you need a 30 W bollard for an upscale housing cluster or a 300 W area light for a logistics yard, the luminaire ships from Jiangmen with your label, your optic, and your carton artwork—already on the ETL & CE on-line directories.
Next Step: From Spec Sheet to Container Load
Send your project’s lux grid, mounting height, and CCT requirement to [email protected].
Our engineers return a dialux report, BOM cost, and production slot within 24 h—backed by 25 years of outdoor LED experience and the certifications your customs broker demands.
Technical Specs & Certifications (ETL/CE)

Technical Specifications & Quality Standards for Outdoor Lighting Solutions
With 25+ years of manufacturing expertise since 1998, Beauty STC combines industrial-scale production with precision engineering to deliver certified outdoor lighting solutions for global markets. Our OEM/ODM capabilities are underpinned by rigorous quality control protocols and third-party certifications, ensuring compliance with North American and European standards.
Photometric Performance Metrics
Outdoor lighting applications demand precise photometric control for safety, security, and energy efficiency. Beauty STC prioritizes high lumen efficacy (measured in lumens per watt) and Color Rendering Index (CRI >90) to ensure optimal visibility and color accuracy. Our products consistently achieve >160 lm/W through optimized LED chip selection and driver integration, reducing operational costs while maintaining output stability. CRI values exceeding 90 ensure accurate color representation critical for architectural detailing and security surveillance. Consistency is maintained through automated photometric testing at every production stage, with tolerances within ±3% for lumen output and color temperature.
Environmental Protection Standards (IP Ratings)
Exposure to rain, dust, and temperature extremes requires robust ingress protection. Beauty STC exceeds industry standards with IP66-rated housings for all outdoor fixtures, verified through TUV-certified testing protocols. This includes rigorous water jet resistance (100L/min at 100kPa) and complete dust tightness, ensuring reliability in coastal, industrial, and high-moisture environments. Each unit undergoes 24-hour environmental stress testing prior to shipment.
PCB Quality and Thermal Management
Thermal management is critical for LED longevity. Beauty STC utilizes high thermal conductivity metal core PCBs (MCPCB) with 1.5–2.0 W/mK ratings, significantly outperforming standard FR-4 alternatives. Our designs incorporate finite element analysis (FEA) for thermal dissipation, with each board subjected to thermal cycling tests (-40°C to +85°C) to validate 50,000+ hour operational life. This ensures stable performance even under continuous 24/7 operation.
Quality Assurance Framework
Beauty STC maintains end-to-end traceability through comprehensive in-house testing protocols. Every product batch is validated against certified test reports from ETL and TUV laboratories, with full documentation provided to clients. Our commitment to innovation drives continuous improvement in manufacturing methodologies, ensuring consistent quality across all OEM/ODM projects.
| Specification | Generic Market Quality | Beauty STC Certified Quality |
|---|---|---|
| Luminous Efficacy | 100–120 lm/W | >160 lm/W |
| CRI (Ra) | 70–80 | >90 |
| IP Rating | IP65 (self-declared, unverified) | IP66 (TUV-certified testing) |
| PCB Material | Standard FR-4 (0.3–0.5 W/mK) | High-Conductivity MCPCB (1.5–2.0 W/mK) |
| Certification Compliance | CE (self-certified), no ETL | ETL (US/Canada), TUV CE (Europe) with full test reports |
| Thermal Management | Passive cooling only | FEA-optimized thermal design |
All specifications validated through third-party testing per international standards. Full test reports available upon request for OEM/ODM projects.
Factory Tour: Manufacturing Excellence

Manufacturing Process & OEM Services – Jiangmen Headquarters
Beauty (STC) Manufacturing Co., Ltd. has operated from a 38 000 m² campus in Jiangmen’s High-Tech Zone since 1998. Every outdoor LED fixture that leaves our dock is built on the same SMT-driven, burn-in verified, ETL/TUV-audited line we use for North-American and European distributors.
1. Production Flow (Outdoor LED Strips, Wall Packs, Area & Flood Lights)
| Stage | Equipment / Protocol | Key Parameter | Record |
|---|---|---|---|
| IQC | RoHS 2.0 XRF scanner, integrating sphere | CRI, SDCM ≤ 5 | Lot # traceable 10 yrs |
| SMT | Juki 2060 & 2080 lines, 0201–5050 pkg | ±25 µm placement, 0.2 % defect | SPI & AOI inline |
| Reflow | 10-zone Heller 1809 MKIII | Peak 245 °C, △T ≤ 5 °C | Profile log / board |
| Waterproofing | PU / silicone extrusion, IP67 IP68 | 100 % 1 h 0.3 MPa immersion | Bar-code to S/N |
| Burn-in | 2 h @ 45 °C → 2 h @ –10 °C, 3 cycles | < 0.5 % lumen drop | Data appended to COA |
| Final QC | 2 kV Hi-pot, 500 V insulation, 1 000 h LM-80 extrapolation | Pass ETL 1598 / CE EN 60598-2-4 | PDF report on request |
2. In-House Capabilities for Outdoor House Lighting OEM / ODM
| Customisation Lever | Range | Tooling Time | MOQ |
|---|---|---|---|
| Length / shape | 50 mm – 5 000 mm (strips), 50 W – 500 W (flood) | 3 – 5 days | 100 pcs |
| CCT / SDCM | 1 800 K – 6 500 K, 3- or 5-step MacAdam | N/A | 1 reel |
| Optics | Type II, III, IV street distributions, 8°–120° floods | 7 days (lens mould) | 200 pcs |
| Bracket / housing | Die-cast ADC12, 316 SS, marine powder coat | 10 days (CNC) | 100 pcs |
| Packaging | White label, skin, retail, FSC carton | 2 days (artwork) | 1 pallet |
| Wireless node | 0–10 V, DALI-2, Zigbee, Bluetooth-Mesh | 5 days (FW flash) | 50 pcs |
3. Certification & Compliance Matrix
| Market | Document | Standard | Lab | Validity |
|---|---|---|---|---|
| USA / Canada | cETLus | UL 1598, UL 8750, CAN/CSA C22.2 #250.0 | Intertek | 2028 |
| Europe | TUV CE | EN 60598-1, EN 60598-2-4, EN 62493 | TUV SUD | 2027 |
| Outdoor IP | IP66/IP67/IP68 | IEC 60529 | SGS | Per product |
| Salt spray | ASTM B117 720 h | ≥ 9 grade | CTI | Per housing batch |
4. Engineering Support for Exterior Projects
- IES & LDT files within 24 h – compatible with AGi32, DIALux, Relux.
- Dialux evo mock-ups – roadway, car park, façade, pathway; we supply iso-lux, veiling luminance, and BUG ratings.
- Sample policy – 48 h dispatch from Jiangmen; freight collect.
- ODM timeline – concept → tooling → pilot run → mass production in 25–30 calendar days (flood/area lights).
5. Logistics & After-Sales
| Region | FOB Port | Weekly Sailings | Transit | Warranty |
|---|---|---|---|---|
| USA West | Shenzhen / Yantian | 3 | 12 days LA | 5 yrs |
| USA East | Shenzhen / Yantian | 2 | 26 days NY | 5 yrs |
| EU | Shenzhen / Nansha | 4 | 24 days Hamburg | 5 yrs |
| AU | Shenzhen / Shekou | 2 | 13 days Sydney | 5 yrs |
All outdoor LED drivers are stocked at 120–277 V 50/60 Hz; 347 V and 480 V options available with 2-week lead-time. Spare-driver kits shipped with first order to minimise call-backs for contractors.
For project quotations or OEM documentation packs, contact:
[email protected] | +86-13902885704
Installation & Application Scenarios

Key Application Scenarios for Commercial Exterior Lighting
Commercial exterior lighting extends beyond basic illumination—it enhances safety, defines architectural identity, and supports operational efficiency across diverse environments. Below are verified application scenarios where engineered lighting solutions deliver measurable value, with technical guidance for contractors.
Hotel Exterior & Landscaping
Hotel properties require layered lighting that balances security, ambiance, and wayfinding. Perimeter floodlights deter unauthorized access, while subtle accent lighting highlights landscaping and architectural features without disrupting guest experience.
| Product Type | Key Specifications | Application Focus |
|---|---|---|
| LED Floodlight | IP67, 100W–200W, 10,000–20,000 lm, 3000K–4000K | Security perimeters, driveways |
| Flexible LED Strip | IP65, 14.4W/m, 2700K–6500K, dimmable | Pathway edges, pool decks |
Contractor Tips:
Mount floodlights at 12–18ft heights for optimal coverage of entry points and parking zones.
Use 12V flexible strips with waterproof connectors for wet areas; ensure 6–8ft spacing for uniform illumination.
Coordinate with landscape architects to avoid glare on guest room windows.
Commercial Facade Integration
Facades demand precise light distribution to emphasize architectural details while minimizing energy use. Modern LED panels and strips enable dynamic color tuning for events or brand identity.
| Product Type | Key Specifications | Application Focus |
|---|---|---|
| LED Panel Light | IP65, 40W–100W, 5,000–10,000 lm, 4000K–5000K | Building outlines, signage |
| Flexible LED Strip | IP67, 14.4W/m, tunable white (2700K–6500K) | Cove lighting, cornices |
Contractor Tips:
Install panels at 1–2ft intervals for even illumination; use 0–10V dimming for after-hours energy savings.
For curved surfaces, select flexible strips with adhesive backing rated for outdoor thermal cycling (-40°C to +60°C).
Validate photometric reports to avoid light trespass into adjacent properties.
Parking Lot & Roadway Safety
Parking lots and roadways require standardized light distribution (Type II, III, IV) to meet IES lighting guidelines. High-output floodlights ensure uniform vertical and horizontal illuminance for safety compliance.
| Product Type | Key Specifications | Application Focus |
|---|---|---|
| LED Floodlight | IP66, 200W–400W, 25,000–50,000 lm, Type III/IV distribution | Parking lots, roadways |
| UFO High Bay | IP65, 150W–300W, 20,000–40,000 lm, 4000K | Covered parking garages |
Contractor Tips:
For Type III distribution (narrow beam), mount fixtures 20–25ft high with 25–30ft spacing; Type IV (wider spread) requires 15–20ft heights and 20–25ft spacing.
Use pole-mounted fixtures with anti-glare baffles to reduce skyglow and comply with dark-sky ordinances.
Verify local codes for minimum foot-candle requirements (e.g., 1.0 fc for residential parking, 2.0 fc for commercial).
Security & Perimeter Lighting
Critical infrastructure and high-security zones demand robust, tamper-resistant fixtures with redundant power options.
| Product Type | Key Specifications | Application Focus |
|---|---|---|
| LED Floodlight | IP68, 300W+, 40,000+ lm, 5000K, PIR motion sensor | Warehouse perimeters, gates |
| Wall-Mount Fixtures | IP67, 100W, 10,000 lm, CCT adjustable | Building entrances, fences |
Contractor Tips:
Install motion-sensor floodlights at 8–10ft heights for facial recognition; avoid obstructions in detection zones.
Use corrosion-resistant aluminum housings for coastal or industrial environments.
Integrate with access control systems via 0–10V or DALI protocols for centralized management.
Installation Best Practices for Contractors
Mounting Height & Spacing Considerations
Proper fixture placement prevents dark spots and over-illumination. Adhere to IESNA RP-8 standards for commercial projects:
| Application | Recommended Mounting Height | Fixture Spacing | Critical Notes |
|---|---|---|---|
| Parking Lot (Type III) | 20–25ft | 25–30ft | Use photometric software for layout validation |
| Pathway (Residential) | 8–10ft | 10–12ft | Avoid direct eye line for pedestrians |
| Facade (High-Rise) | 15–20ft | 10–15ft | Account for building shadowing |
Electrical Compliance & Safety
Non-compliant wiring is the leading cause of field failures. Key protocols:
Wire Gauge: Minimum 10 AWG for 120V runs over 50ft; use UV-resistant UF-B cable for direct burial.
Grounding: Install GFCI protection for all outdoor circuits; verify earth resistance <25 ohms per NEC Article 250.
Control Systems: For smart lighting, ensure DMX/DALI controllers are rated for outdoor use (IP65+).
Environmental Protection Measures
Outdoor fixtures face thermal stress, moisture, and UV degradation. Mitigate risks with:
Sealing: Apply silicone-based sealant to all conduit entries; use compression fittings for cable glands.
Material Selection: Die-cast aluminum housings outperform plastic in high-UV environments; stainless steel hardware prevents corrosion.
Thermal Management: Ensure 2–3in clearance around heat sinks; avoid mounting near heat sources (e.g., HVAC units).
Engineering-Grade Reliability for Global Projects
Beauty STC Lighting has delivered engineered lighting solutions since 1998, with 25+ years of manufacturing expertise supporting complex global projects. All products undergo rigorous testing to ETL (USA/Canada) and TUV CE (Europe) standards, ensuring compliance with regional safety, performance, and energy regulations. Our OEM/ODM capabilities include:
Custom photometric designs tailored to IES distribution types (II, III, IV)
Material adaptations for extreme climates (e.g., salt spray resistance for coastal deployments)
Integration with smart control systems (DALI, Zigbee, 0–10V)
As a responsible manufacturer, we prioritize sustainable production processes and long-term reliability—eliminating costly replacements and reducing total lifecycle costs for contractors.
For project-specific technical support or OEM inquiries:
[email protected] | +86 13902885704
41st, Caihong Road, High-tech Industrial Zone, Jianghai District, Jiangmen, Guangdong, China
Why Choose Beauty STC Lighting

Partner with Beauty STC Lighting
Factory-direct, specification-grade LED modules for façade, site & landscape projects
| Factory Credentials | Certification | Geographic Reach |
|---|---|---|
| Established 1998 – 25 yrs continuous LED production | ETL cETL (US/Canada) – file 5013348 | Exported to 50+ countries |
| 18 000 m² Jianghai high-tech zone plant | TUV CE / CB / RoHS (EU) | Europe, N-America, AU, RU, JP, KR, SE-Asia |
OEM / ODM Capabilities – Exterior Lighting Building Blocks
| Core Platform | Typical Outdoor Derivatives | Value-add Services |
|---|---|---|
| 24 V & 48 V constant-voltage LED strip, IP67/IP68, 180–240 lm/ft | Silicone-neon jacketed façade outlines, cove & soffit lighting | Length, CCT, CRI, binning to ±3 SDCM |
| 130–200 lm/W LED panel, 0–10 V / DALI / emergency options | Surface or recessed ceiling modules for covered patios & transit canopies | Custom extrusions, IP54–IP65 gaskets |
| 100–400 W LED floodlight, 3000–5700 K, 30×120° to 90×120° optics | Wall-wash, flag-pole, sign & landscape flood kits | Integral 3-pin NEMA socket, Zhaga book-18 for smart node |
| 100–240 W UFO high-bay, 140 lm/W, –40 °C to +50 °C | Pole or trunnion mount area lights (IES Type II, III, IV) | Motion/hi-lo, solar-ready DC input |
Specification Compliance – Ready for Western Submittals
Photometry: IES, LDT, TM-30, BUG ratings available on request
Surge: 6 kV (DM) / 10 kV (CM) per IEEE C62.41.2
Salt-spray: 1000 h ASTM B117 for coastal façades
Vibration: 3 g MIL-STD-202G for bridge & parking-garage installs
5-year standard warranty, extendable to 10 years with LM-80 & TM-21 data pack
Next Step – Engineering Samples & Project Quotes
Send us your lux plots, mounting heights and required BUG/IES distribution.
Our optical & thermal engineers will return a matched BOM, dialux report and landed cost within 48 h.
Contact:
[email protected]
+86-139 0288 5704 (WhatsApp / WeChat)
41F, Caihong Road, High-tech Industrial Zone, Jianghai, Jiangmen, Guangdong, CN
⚡ LED Power Supply Calculator
Calculate the required power supply for your LED strip project (includes 20% safety margin).