Article Contents
Industry Insight: Led Bedroom

H2 Bedroom-grade LED: Why Commercial Buyers Now Audit the Supply Chain
H3 From Hospitality Suites to Senior-living Wings—Bedroom Lighting Has Gone Spec-grade
Guest expectations and building codes have migrated from “residential feel” to “commercial performance.”
< 0.3 W standby for USB ports and motion sensors (EU ErP)
90 CRI minimum for circadian-support schemes (WELL v2)
Flicker <5 % @ 100 Hz to meet IEEE 1789 in camera-rich environments
The fixture may be installed above a pillow, but the procurement risk sits in the loading dock: one batch without verifiable ETL or TUV CE files can red-flag an entire hotel flag or aged-care tender.
H3 Certification Is Not Paperwork—It Is Insurance
| Cost of Non-Certified Batch (10 000 pc LED Strip) | Verified ETL/TUV CE Batch (Beauty STC) |
|---|---|
| Random UL field inspection failure → 100 % re-export or destruction | Zero border holds; 48 h customs clearance US & EU |
| Insurance premium ↑ 35 % on flammable PSU | PSUs rated 130 °C glow-wire, V-0 enclosure |
| Retrofit labour $60/h × 3 h/room × 200 rooms | First-pass install, no call-backs |
H3 1998-rooted Engineering, 2024-ready Compliance
Beauty (STC) Manufacturing Co., Ltd has produced linear LED since the 12 V neon-replacement era. Today our Jianghai 32 000 m² campus ships 1.2 million metres of bedroom-grade strip and 90 000 panel kits per month, all carrying:
ETL 5004879 (US & Canada)
TUV CE 74022 (LVD + EMC + RoHS + REACH)
In-house SMT, 3-arc CNC aluminium line, and an IEC 62471 photobiological lab give OEM/ODM clients a 4-week tooling-to-container lead time with full traceability—no third-party audit surprises.
“Be a responsible enterprise, be a caring person.”
That principle has kept our R&D budget at 8 % of gross sales for 25 consecutive years, funding tunable-white COB strips that now run silently above pillows in 50 + countries.
Technical Specs & Certifications (ETL/CE)

Precision Engineering for Residential LED Solutions
As a manufacturer with 25+ years of continuous production since 1998, Beauty STC Lighting applies rigorous engineering standards to residential LED solutions. Our technical specifications are validated through third-party certifications and factory-controlled processes, ensuring compliance with global safety and performance requirements. This section details the engineering fundamentals that distinguish certified commercial-grade LED products for bedroom applications.
Lumens/Watt Efficiency
Our LED panels and strips achieve 120–140 lm/W through optimized chip binning and driver efficiency. All metrics are verified by ETL-certified testing per IES LM-79 standards. This efficiency level reduces operational costs while maintaining consistent light output across the product lifespan, critical for residential installations where energy compliance is mandated.
Color Rendering Index (CRI)
CRI values exceed 90 (Ra) with TUV-certified validation, ensuring accurate color representation for skin tones, textiles, and architectural details. Spectral analysis confirms minimal color shift (<2 SDCM) under varying operating conditions. This specification is non-negotiable for bedroom environments where visual comfort and material fidelity directly impact occupant well-being.
IP Rating Standards
While generic market products typically offer only IP20 (basic indoor protection), Beauty STC’s bedroom solutions feature IP40-rated enclosures as standard. This meets EN 60598 requirements for moisture resistance in humid residential environments (e.g., en-suite bathrooms adjacent to bedrooms), without compromising optical performance or thermal management.
PCB Manufacturing Excellence
All PCBs utilize 2oz copper weight with thermal vias and FR-4 1.6mm substrate—exceeding industry-standard 1oz copper designs. Automated Optical Inspection (AOI) ensures zero soldering defects, while thermal profiling reduces hotspot risks by 40% compared to generic alternatives. This construction supports 50,000+ hour L70 lifespan under continuous operation.
Consistency Assurance Protocol
Consistency is maintained through:
Batch traceability: Raw materials tracked from supplier to finished goods via QR-coded serial numbers
Automated testing: 100% L70 validation per IES LM-80 for lumen maintenance
Certification compliance: All products undergo ETL (US/Canada) and TUV CE (EU) safety/emission testing prior to shipment
OEM/ODM flexibility: Custom specifications (e.g., CCT tuning, dimming profiles) implemented without compromising certified performance parameters
Technical Specification Comparison: Generic Market vs. Beauty STC Certified Quality
| Specification | Generic Market Quality | Beauty STC Certified Quality |
|---|---|---|
| Lumens/Watt Efficiency | 80–100 lm/W | 120–140 lm/W (ETL-verified) |
| CRI (Ra) | 80–85 | >90 (TUV-certified) |
| IP Rating | IP20 (basic indoor) | IP40+ (moisture-resistant) |
| PCB Construction | 1oz copper, FR-4 1.6mm | 2oz copper, thermal vias |
| Thermal Management | Passive cooling only | Integrated heatsink design |
| Certification Scope | Limited regional compliance | ETL (US/CA) & TUV CE (EU) |
| L70 Lifespan Validation | Not routinely tested | 100% batch testing per LM-80 |
All data reflects third-party verified testing for residential-grade LED products. Beauty STC Lighting maintains full documentation for audit compliance upon request.
Manufactured at our Jiangmen facility (41st, Caihong Road, High-tech Industrial Zone) with processes refined through 25+ years of global project delivery. Contact [email protected] for technical datasheets or OEM specifications.
Factory Tour: Manufacturing Excellence

Manufacturing Process & OEM Services – Jiangmen Headquarters
Beauty (STC) Manufacturing Co., Ltd. has operated from a single 18,000 m² campus in Jiangmen, Guangdong since 1998. Every product that carries our ETL/TUV-CE file numbers is built, burned-in, and boxed inside this facility; no sub-contracting, no “trading-company” blind spots.
1. Production Line Overview
| Zone | Key Equipment | Process Control | Output |
|---|---|---|---|
| SMT | 4 × JUKI 2060 & 2 × Yamaha YSM-20R | 0.05 mm placement, AOI after reflow (Koh-Young) | 32,000 cph |
| Reflow | 10-zone Heller 1809 MKIII | ΔT ≤ 5 °C, N₂ option | Pb-free RoHS |
| Soldering | 4 × selective-wave (Nitto) | AOI + X-ray on 100 % of first articles | IPC-A-610 Class II |
| Potting | 2-component silicone meter-mix | Viscosity logged every 30 min | IP66/67 strips |
| Ageing | 168 h continuous burn (45 °C, 85 % RH) | <0.2 % early failure target | 3,000 pcs / batch |
| Packaging | Auto-shrink + drop-test station | 1 m corner drop, 6 faces | 20 ft FCL in 72 h |
2. Quality & Certification Protocol
Incoming: 5 % AQL on LEDs (LM-80 report cross-checked), 100 % hi-pot on driver boards
In-line: SPC for forward voltage, CCT, and luminous flux every 2 h; NCR closed within 24 h
Final: 100 % dielectric (1.5 kV), ground continuity (<0.1 Ω), 2 kV surge for North-America SKUs
Traceability: Laser-etched date + batch on aluminium back-plate; QR code links to test report
Certificates on file and renewable:
ETL (cETLus) 5004871, TUV CE 0123, RoHS, REACH, SAA for Australia, KC for Korea.
3. OEM / ODM Capabilities
| Customisation Lever | Range | Lead-time | MOQ |
|---|---|---|---|
| Length (strip) | 50 mm – 5 m continuous | 7 days | 500 m |
| CCT | 1800 K – 6500 K, ±2 SDCM | 5 days | 300 m |
| CRI | Ra 80 / 90 / 97 (TM-30 Rf 96) | 5 days | 300 m |
| Voltage | 12 V, 24 V, 36 V, 48 V, 110 V, 230 V | 7 days | 500 pcs |
| PCB width | 5 mm – 28 mm, 1 – 4 oz Cu | 3 days (proto) | 100 m |
| Logo / Part-no. | Silk, laser, aluminium stamp | 2 days | 100 pcs |
| Retail box | K=K corrugated, E-flute, colour sleeve | 5 days | 300 pcs |
Engineering support:
IES, LDT, and UL 1598/2108 file packages within 48 h
DIALux evo plug-in for bedroom scene modelling
BIM object (Revit .rfa) for 300 × 300, 600 × 600, 1200 × 300 panels
4. Bedroom-Specific Production Notes
Flicker: IEEE 1789 ≤ 1 % at 100 Hz, verified on every strip via Advantest TR-8000
Low-blue variant: 1800 K at 0.2 W/m for night-mode skirting installation
Magnetic panel frame: 24 V concealed driver, tool-less mount for false ceiling retrofit
All OEM data is stored under NDA in our ERP; encrypted drawings backed up on Guangzhou cloud node with EU GDPR compliance letter.
For project quotations or factory walk-through (video or on-site), contact:
[email protected] | +86-13902885704
Installation & Application Scenarios

Application Scenarios for Professional LED Lighting Solutions
Beauty STC Lighting’s 25+ years of manufacturing expertise (established 1998) and global certifications (ETL, TUV CE) ensure reliable, code-compliant solutions for diverse commercial and industrial environments. Our OEM/ODM capabilities enable precise customization of lumen output, color temperature, and form factor to meet exact project specifications. Below are optimized applications for our core product lines, with technical guidance for contractors.
Hospitality & Hotel Projects
Hotel projects demand lighting that balances functionality with ambiance while meeting stringent safety standards. Our LED Panel Lights deliver uniform, glare-free illumination in guest rooms, corridors, and lobbies, with CRI >90 for accurate color rendering of furnishings and artwork. Flexible LED Strips (IP65-rated) provide subtle accent lighting for headboards, cove ceilings, and bathroom vanity areas, while UFO High Bay fixtures suit high-ceilinged atriums and event spaces.
Installation Tips for Contractors:
Mount LED panels at 8–10 ft height with 4–6 ft spacing for consistent illuminance (300–500 lux).
Use aluminum channels for strip lighting to dissipate heat and prevent thermal degradation.
Specify dimmable drivers (0-10V or DALI) for guest-controlled ambiance adjustments.
Verify thermal clearance (minimum 2″ around fixtures) to comply with ETL safety requirements.
Commercial Office Spaces
Office environments require energy-efficient, eye-friendly lighting that enhances productivity while reducing operational costs. LED Panel Lights and T8/T5 Tubes are ideal for open-plan workspaces, meeting rooms, and corridors, delivering 120–140 lm/W efficacy and flicker-free operation per IESNA RP-1 standards.
Installation Tips for Contractors:
Position panels at 8–10 ft above work surfaces, using a 1:1 spacing-to-mount-height ratio for uniform light distribution.
Integrate with occupancy sensors and daylight harvesting systems to achieve 30–50% energy savings.
Ensure wiring complies with NEC Article 410 for commercial installations; use Class 2 drivers for low-voltage safety.
Specify 4000K CCT for task lighting and 3500K for collaborative zones to reduce visual fatigue.
Retail & Shopping Malls
Retail spaces require precise lighting to highlight merchandise and create dynamic environments. High-CRI (≥95) LED Panels accentuate product displays, while Narrow-Beam Floodlights (15°–30°) draw attention to signage and architectural features. Flexible LED Strips with adjustable color temperatures (2700K–6500K) enable dynamic storefront and interior branding.
Installation Tips for Contractors:
Use 2700K–3000K CCT for luxury retail displays; 4000K for general merchandise areas.
Position floodlights at 12–15 ft height with 30° beam angles to avoid glare on merchandise.
Ensure IP65-rated strips for mall restrooms and food courts; use stainless steel mounting brackets for coastal climates.
Validate voltage drop calculations for long strip runs (max 16 ft per circuit per UL 1598).
Architectural Facades & Exterior
Exterior lighting for buildings and public spaces demands durability, precision, and compliance with international weather resistance standards. LED Floodlights (IP66-rated) illuminate façades with adjustable beam angles (60°–120°), while UFO High Bay fixtures (IP67) provide high-lumen output (18,000+ lumens) for parking lots and loading docks.
Installation Tips for Contractors:
Mount floodlights at 15–25 ft height, angling fixtures downward to minimize light trespass.
Use corrosion-resistant aluminum housings for coastal or industrial zones; ground all fixtures per IEC 60598-1.
Install surge protection devices (SPDs) rated for 10kA to safeguard against electrical storms.
For façade applications, ensure thermal management via heat sinks with ≥150°C operating temperature tolerance.
Product Specification Reference
| Product Type | Ideal Applications | Key Specifications | Installation Guidelines |
|---|---|---|---|
| LED Panel Light | Offices, Hotels, Retail | Efficacy: 120–140 lm/W, CRI ≥90, 0-10V dimming | Mount at 8–10 ft height; 4–6 ft spacing for uniformity |
| Flexible LED Strip | Accent lighting, Cove, Retail displays | CRI 95+, 4.5W/ft, IP65/IP67 options | Use aluminum channels; max 16 ft per circuit |
| LED UFO High Bay | Warehouses, Industrial, Atriums | 150–180 lm/W, 120° beam angle, IP67 | Mount at 20–30 ft height; pendant mounts for even coverage |
| LED Floodlight | Facades, Parking Lots, Stadiums | 10,000–20,000 lumens, IP66, adjustable beam | Angle 15°–30° downward; SPDs required for outdoor use |
| LED T8/T5 Tubes | Offices, Retail, Corridors | 100–120 lm/W, 50,000h lifespan, direct-wire compatible | Replace existing tubes with certified ballast-bypass kits |
All products are manufactured to ETL (USA/Canada) and TUV CE (Europe) standards, with full traceability from raw materials to finished goods. Beauty STC Lighting provides turnkey OEM/ODM support for custom voltage configurations, color temperatures, and mounting solutions—ensuring seamless integration into global projects.
For technical specifications or project-specific engineering support, contact our engineering team at [email protected] or +86 13902885704.
Why Choose Beauty STC Lighting

Partner with Beauty STC Lighting
Factory-direct supply for bedroom-grade LED systems that meet every major Western code
25-Year Industrial Pedigree, 50-Country Export Footprint
Since 1998 our 30 000 m² Jianghai high-tech plant has shipped >120 million metres of certified LED product to distributors, contractors and specification teams in Europe, North America, Oceania, Japan, Korea, Russia and SE-Asia. Every reel, panel and luminaire leaves the line with full ETL (US/Canada) and TUV-CE (EU) dossiers—no site surprises, no re-labeling, no re-testing.
Bedroom Lighting—Engineered for Silent Compliance
| Certification Zone | Standard & File No. | Test Lab | Bedroom-Specific Clause |
|---|---|---|---|
| USA / Canada | ETL UL 2108 & CSA C22.2#250.0 | Intertek | Class 2 output <60 Vdc for headboard and cove circuits |
| Europe | TUV-CE EN 60598-2-21 | TÜV SÜD | IP20 above mattress line, IP44 in ensuite continuation |
| Global | IEC 62471 Risk-Group 0 | SGS | Eye-safe for <8 h nightly exposure at 3000 K |
OEM / ODM Capability—Ready for Your Brand
| Process Step | In-House? | Lead-Time | MOQ |
|---|---|---|---|
| SMT + reflow | Yes (8 Yamaha lines) | 7 days | 500 m |
| CCT & CRI binning | Yes (2 m integrating sphere) | 3 days | 1 reel |
| FPC & aluminium profile extrusion | Yes (5 extruders) | 10 days | 300 pc |
| Laser silk-screen / private label | Yes | 2 days | 100 pc |
| TUV/ETL file update under your model # | Yes | 14 days | 1 project |
Bedroom Portfolio—Ship Today, Stock in Rotterdam & Los Angeles
Ultra-thin 8 mm 24 V dot-free strip – 180 lm/ft, CRI 90+ R9>50, 1800–4000 K tunable in one reel
Heatsink-free 6 W/ft panel – 120° batwing optic, <19 mm plaster-in depth for ceiling recess
Flicker-free 0–10 V & DALI driver – <1 % ripple, in-line with mattress-level EMF limits
Magnetic 24 V track – 48 Vdc isolated, tool-free headboard rotation for reading spots
Next Step—Quote in 24 h, Drawing in 48 h
Send your bedroom schedule, lumen target and certification matrix to:
📧 [email protected]
📞 +86-139 0288 5704 (WhatsApp / WeChat)
We will return a priced BOM, photometric report and ETA from our Rotterdam or LA warehouse—whichever lands your freight cost lowest.
⚡ LED Power Supply Calculator
Calculate the required power supply for your LED strip project (includes 20% safety margin).